| OXYGEN GAS ANALYZERS : | |||
![]() |
Handy Oxygen Gas Analyzer : | ||
|
The 'Nucon Series - 100' Handy Oxygen Gas Analyzer are designed for accurate and reliable measurement of Oxygen in Air, Nitrogen, Argon, Hydrogen etc. These are based on state of art Galvanic Oxygen Sensors, and provide fast response. They require no periodic maintenance like replacing electrodes or electrolyte and can be calibrated using ambient air or standard calibration samples. A digital display provides direct percentage output readout. The power Source is a 9V battery. Use of C MOS integrated Circuits ensures low power consumption for long battery life. Model 101 is an Oxygen Monitor for general applications. Model 102 additionally has low Oxygen set alarm facility which is usually preset to 19.0 % intended for personal safety usage and warns if Oxygen level falls below acceptable to human system. | |||
| Specifications: | Special Features : | ||
|
Ü Range : 0.0% - 25.0% with least count 0.1%. |
Ü Pocket Size. | ||
| Applications : | |||
| Ü Gas Purity check. Ü Combustion Efficiency Ü Glove Boxes. Ü Cryogenics. Ü Microbiology. Ü Metallurgy. Ü Chemical Engineering. Ü Plastic manufacturing. |
Ü Food & Beverages packing.
| ||
![]() |
Percentage Oxygen Gas Analyzer : | ||
|
The 'Nucon Series - 4000' Percentage Oxygen Gas Analyzers cover the range 0.01% to 100% and provide continuous analysis of oxygen in industrial gas streams. These are Panel Mounted instruments with optional back stand can also be used for Bench Top applications. The transducer is sealed electro chemical fuel cell that generates signal in direct linear porportion to the oxygen concentration in the sample stream. It requires no periodic maintenance like replacing electrodes or electrolytes and can be calibrated using ambient air or standard samples. The Output is available on a digital readout with a reslolution of 0.1 % or 0.01% depending upon model. Recorder terminals are provided on back panel. Series 4000 is available in two measuring ranges and
each range has option of two flow configurations. Model 4000 and
4406 cover the range 30.0%. Models 4440 and 4446 cover the range
0-100.0 % and are recommended where high percentage is to be
monitored. Models 4400 and 4440 are simple flow inlet instruments
useful for low pressure flows. However where sample is available
from pressurised sources and other special features are required, models
4406 and 4446 are recommended; these have, in addition, flow
regulation, flow reading (rotameter) and Oxygen Cell Isolation valves
provided in the flow circuit for the transducer. Model 4400A has
built-in sensor in diffusion mode for atmospheric monitoring; where Remote
Diffusion Sampling is required Model 4404 is recommended. All Models
have alarm set facility available on a ten turn direct reading dial and
the output is a one pole two way relay with potential free NO, C, NC
contacts brought out on the back
panel. | |||
| Specifications: | |||
|
Ü
Range : Model
4400,4404 : 0-30.0
%, Resolution : 0.1 %. | |||
| Applications : | |||
| ÜGas Purity check. ÜCombustion Efficiency Studies ÜGlove Boxes. ÜCryogenics. ÜMicrobiology. ÜMetallurgy. ÜChemical Engineering. ÜPlastic manufacturing. |
Ü Food & Beverages packing.
| ||
Nucon Digital Trace
Oxygen Gas Analyzer are designed for accurate and reliable measurement of
Trace oxygen concentration. Bench Top Model 4316 or Panel Mounting
Model 4316P versions are available. These are complete instruments
and no additional flow regulating, flow monitoring and oxygen cell
Isolation Valves are required to be connected externally. Direct use
on pressurised source like gas cylinder or pipeline is possible. The
instrument will measure Oxygen at ppm levels in presenec of most
industrial and laboratory gases and atmospheres. It requires no
periodic maintenance like replacing electrodes or electrolite and can be
calibrated using ambient air or standard calibration samples. The
transducer is a sealed electrochemical fuel cell. Alarm set facility
is available on a ten trun direct indicating dial. Ü Food & Beverages packing.

Trace Oxygen Gas
Analyzer :

Specifications:
Ü
Range
Ü
Resolution
Ü
Power Supply
Ü
Display
Ü
Response Time
Ü
Sample Gas Pressure
Ü
Sample
ConnectionPercentage
for calibration if by air and 0-2000 ppm for monitoring.
1
ppm for Model 4316 and 0.1
ppm for Model 4316P.
220
V A.C.
Digital.
90
% within 25 seconds.
0.1-10.0
Kg/Cm.Sq.
1/8"
tube connection.
Special Features
:
Ü
Flow Monitoring and control are standard
features.
Ü
Alarm with indicating light and SPDT relay are
standard features.
Ü
Specific to Oxygen.
Ü
Insensitive to sample flow rate in operating
region.
Ü
Simple to
Operate.
Ü
Maintenance free dispoable measuring
cell
Ü
Air calibration check.
Ü
Sturdy construction.
Ü
Cell Isolation Valve to protect cell while
not in
use.
Applications :
Ü Gas Purity check.
Ü
Inert atmosphere gas blanketing
monitoring.
Ü Glove Boxes.
Ü Cryogenics.
Ü Lamp and bulb
manufacturing.
Ü Metallurgy.
Ü Chemical Engineering.
Ü Plastic
manufacturing
Ü
Bio-Technology.
Ü Electronics.
Ü Controlled gas
environment.